Search results for "TOTAL OZONE"
showing 8 items of 8 documents
Analysis of winter dust activity off the coast of West Africa using a new 24-year over-water advanced very high resolution radiometer satellite dust …
2006
A 24-year (1982-2005) winter daytime advanced very high resolution radiometer (AVHRR) data set has been processed utilizing a new over-water dust detection algorithm. The dust data are for the oceanic regions surrounding West Africa and provide a long-term remotely sensed continuous record of dustiness in the region. These AVHRR dust observations are comparable to dust records produced via the Total Ozone Mapping Spectrometer and Meteosat instruments. Strong positive correlations between the wintertime Jones North Atlantic Oscillation index and this dust record are observed across the entire oceanic region, corroborating earlier studies on the relationship between the two. Also consistent w…
In search of traceability: two decades of calibrated Brewer UV measurements in Sodankylä and Jokioinen
2016
Abstract. The two Brewer spectrophotometers of the Finnish Meteorological Institute at Jokioinen and Sodankylä have been operated according to the highest levels of the WMO∕GAW (World Meteorological Organization∕Global Atmosphere Watch) recommendations with rigorous quality control and quality assurance. The calibration of the instruments is based on annual recalibrations of primary standard lamps in the VTT MIKES Metrology National Standards Laboratory in Finland and an exhaustive measurement program with measurements of standard and working lamps in the on-site optical laboratories. Over the years, the maintenance of the calibration has produced data sets of approximately 2000 lamp scans …
Operational considerations to improve total ozone measurements with a Microtops II ozone monitor
2012
A Microtops II "ozone monitor" with UV channels centered at 305.5, 312.5, and 320 nm has been used routinely in six experimental campaigns carried out in several geographic locations and seasons, covering latitudes from 35 to 68° N during the last ten years (2001–2011). The total ozone content is retrieved by Microtops II by using different combinations (Channel I, 305.5/312.5 nm; Channel II, 312.5/320 nm; and Channel III, 305.5/312.5/320 nm) of the signals at the three ultraviolet wavelengths. The long-term performance of the total ozone content determination has been studied taking into account the sensitivities to the calibration, airmass, temperature and aerosols. When a calibration was…
Ozone mini-holes over Valencia (Spain) and their influence on the UV erythemal radiation
2010
Low ozone level episodes (also known as mini-holes) have been analysed over Valencia, Spain, during the period from 1 January 2000 to 31 December 2007. In this study, 24 episodes, lasting 1 or 2 days each, were detected. Most of them can be explained dynamically by the existence of an anticyclone over the Azores, which sends air masses coming from the Caribbean over the Iberian Peninsula. A positive anomaly in the vertical temperature profile in the high troposphere and one negative anomaly in the medium and low stratosphere are also observed in most of the analysed episodes. The total ozone column decrease is accompanied by a rise in the UV erythemal radiation levels. This increase is quan…
Stratospheric sulfur and its implications for radiative forcing simulated by the chemistry climate model EMAC
2015
Multiyear simulations with the atmospheric chemistry general circulation model EMAC with a microphysical modal aerosol module at high vertical resolution demonstrate that the sulfur gases COS and SO2, the latter from low-latitude and midlatitude volcanic eruptions, predominantly control the formation of stratospheric aerosol. Marine dimethyl sulfide (DMS) and other SO2 sources, including strong anthropogenic emissions in China, are found to play a minor role except in the lowermost stratosphere. Estimates of volcanic SO2 emissions are based on satellite observations using Total Ozone Mapping Spectrometer and Ozone Monitoring Instrument for total injected mass and Michelson Interferometer fo…
Improvement of the Valencia region ultraviolet index (UVI) forecasting system
2012
The CEAM Foundation (Valencia, Spain) has developed an operational ultraviolet index (UVI) forecasting system based on the Santa Barbara DISORT Atmospheric Radiative Transfer (SBDART) model. The main objective of this system is to provide the general public with a tool to minimize the impact of ultraviolet (UV) radiation, which can cause important human health problems. The system presented in this paper has been developed in collaboration with the Environment Department of the Regional Government of Valencia, and it replaces the one running until 2007. The new system substitutes the previously used Ozone Monitoring Instrument (OMI) observed data with the total ozone column data forecasted …
Ten years of measured UV Index from the Spanish UVB Radiometric Network.
2013
An analysis is made of the UV Index (UVI) obtained from the ultraviolet erythemal solar radiation (UVER) data measured by the Spanish UVB Radiometric Network between the years 2000 and 2009. Previously, the daily UVI has been evaluated using two different criteria: (a) the value corresponding to solar noon; and (b) the daily maximum value. The mean percentage of agreement is 92% if we consider the cases for which the difference is zero or one UVI unit. These results are similar to those obtained in a previous work where only 2 years were analyzed. In all the stations the UVI reaches very high values (8-10) in spring-summer, and the very high and extreme (≥ 11) UVI values are more dependent …
A comparison of Microtops II and satellite ozone measurements in the period 2001-2011
2013
Daily average total ozone Microtops measurements obtained during several campaigns conducted from 2001 to 2011 at latitudes from 31 to 68N and in different seasons are compared with satellite observations. The Microtops ozone is derived using different wavelength combinations (Channel I, 305.5/312.5. nm; Channel II, 312.5/320. nm; and Channel III, 305.5/312.5/320. nm). Satellite data from TOMS, OMI, GOME, and GOME-2 are used in the comparison. The three Microtops channels show a high correlation with the satellite retrievals. Channel I shows the best results and produces a mean bias deviation (MBD) less than 2.14% with respect to TOMS, OMI and GOME. The MBD increases to 3% in the comparison…